Ethernet Group Alarm
This alarm is applicable only to Mediant 500, Mediant 500L, Mediant 800, Mediant 1000, Mediant 3100, Mediant 2600, Mediant 4000, Mediant 9000, and Mediant Software.
acEthernetGroupAlarm
Alarm |
acEthernetGroupAlarm |
||
---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.86 |
||
Description |
The alarm is sent when an Ethernet port in an Ethernet Group goes down. Note: If an Ethernet Group is configured with two ports and only one port goes down, the alarm is not sent. |
||
Default Severity |
Major |
||
Event Type |
equipmentAlarm |
||
Probable Cause |
underlyingResourceUnavailable |
||
Alarm Text |
Ethernet Group alarm. %s |
||
Severity |
Condition |
Text |
Corrective Action |
Major |
Ethernet Group is configured with only one port and the port is down. |
"Ethernet Group alarm. Ethernet Group <ID> is Down" |
- |
Major |
Ethernet Group is configured with two ports and both ports are down. |
"Ethernet Group alarm. Ethernet Group (ID> is Down" |
- |
Cleared |
Ethernet Group configured with only one port: alarm cleared when the port comes up again. Ethernet Group configured with two ports: alarm is cleared when at least one port comes up again. |
- |
- |