Ethernet Group Alarm

This alarm is applicable only to Mediant 500, Mediant 500L, Mediant 800, Mediant 1000, Mediant 3100, Mediant 2600, Mediant 4000, Mediant 9000, and Mediant Software.

acEthernetGroupAlarm

Alarm

acEthernetGroupAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.86

Description

The alarm is sent when an Ethernet port in an Ethernet Group goes down.

Note: If an Ethernet Group is configured with two ports and only one port goes down, the alarm is not sent.

Default Severity

Major

Event Type

equipmentAlarm

Probable Cause

underlyingResourceUnavailable

Alarm Text

Ethernet Group alarm. %s

Severity

Condition

Text

Corrective Action

Major

Ethernet Group is configured with only one port and the port is down.

"Ethernet Group alarm. Ethernet Group <ID> is Down"

-

Major

Ethernet Group is configured with two ports and both ports are down.

"Ethernet Group alarm. Ethernet Group (ID> is Down"

-

Cleared

Ethernet Group configured with only one port: alarm cleared when the port comes up again.

Ethernet Group configured with two ports: alarm is cleared when at least one port comes up again.

-

-